Cool Automation 7000F Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Non Cool Automation 7000F. CoolMaster Programmers Reference Manual (PRM) Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
© 2015 Cool Automation LTD
CoolMaster Programmers Reference Manual (PRM)
Document Revision 4.06 1/7/2015
CoolMaster
www.coolautomation.com
Interface Adapter
for VRV, VRF
Air Conditioning Systems
Cool Master 1000D
Cool Master 2000S
Cool Master 3000T
Cool Master 4000M
Cool Master 6000L
Cool Master 7000F
Cool Master 8000I(MH)
Cool Master 9000H
Cool Master G
Vue de la page 0
1 2 3 4 5 6 ... 27 28

Résumé du contenu

Page 1 - CoolMaster

© 2015 Cool Automation LTDCoolMaster Programmers Reference Manual (PRM)Document Revision 4.06 1/7/2015CoolMasterwww.coolautomation.comInterface A

Page 2 - Table of Contents

Commands ReferenceCoolMaster PRM10www.coolautomation.com© 2015 Cool Automation LTDRev 4.06DESCRIPTIONTurn on all indoor units. EXAMPLE>allon

Page 3 - 3Contents

Commands ReferenceCoolMaster PRM11www.coolautomation.com© 2015 Cool Automation LTDRev 4.06DESCRIPTIONSet indoor unit UID mode to DRY. EXAMPLE>dry

Page 4 - 1 Revisions History

Commands ReferenceCoolMaster PRM12www.coolautomation.com© 2015 Cool Automation LTDRev 4.06COMPATIBILITYCoolMaster 1000Dv 2.5.1CoolMaster 2000Sv 2.8.6C

Page 5 - 2 RS232 Interface

Commands ReferenceCoolMaster PRM13www.coolautomation.com© 2015 Cool Automation LTDRev 4.06CoolMaster 3000TanyCoolMaster 4000ManyCoolMaster 6000LN.A.Co

Page 6 - 2.2 Port Settings

Commands ReferenceCoolMaster PRM14www.coolautomation.com© 2015 Cool Automation LTDRev 4.06>off 102 OK

Page 7 - 3.2 Indoor Unit Addressing

Commands ReferenceCoolMaster PRM15www.coolautomation.com© 2015 Cool Automation LTDRev 4.06>on 012 2 OK

Page 8

Commands ReferenceCoolMaster PRM16www.coolautomation.com© 2015 Cool Automation LTDRev 4.06lcd : 8simul : 0CS count: 0TO count: 0Collisio: 0NA Co

Page 9 - 4 Commands Reference

Commands ReferenceCoolMaster PRM17www.coolautomation.com© 2015 Cool Automation LTDRev 4.06DESCRIPTIONGet Indoor unit(s) status. Specific indoor unit c

Page 10 - 4.1.5 dry

Commands ReferenceCoolMaster PRM18www.coolautomation.com© 2015 Cool Automation LTDRev 4.06OK Position in StringExampleForm

Page 11 - 4.1.7 auto

Commands ReferenceCoolMaster PRM19www.coolautomation.com© 2015 Cool Automation LTDRev 4.0612-1724,08CNN,NNC***Room Temperature ºC20-23AutoLow,Med,High

Page 12 - 4.1.9 filt

2Contents2CoolMaster PRMwww.coolautomation.com© 2015 Cool Automation LTDTable of ContentsPart IRevisions History4Part IIRS232 Interface5...

Page 13 - 4.1.10 fspeed

Commands ReferenceCoolMaster PRM20www.coolautomation.com© 2015 Cool Automation LTDRev 4.06101 OFF 32C 04C Low Dry OK 0 OK

Page 14 - 4.1.12 on

Commands ReferenceCoolMaster PRM21www.coolautomation.com© 2015 Cool Automation LTDRev 4.064.1.18 querySYNOPSISquery <UID> <o|m|f|t|e|a|h>D

Page 15 - 4.1.13 set

Commands ReferenceCoolMaster PRM22www.coolautomation.com© 2015 Cool Automation LTDRev 4.06OK >query 100 f 2

Page 16 - 4.1.15 stat

Commands ReferenceCoolMaster PRM23www.coolautomation.com© 2015 Cool Automation LTDRev 4.06COMPATIBILITYCoolMaster 1000Dv2.5.1CoolMaster 2000Sv2.3.1Coo

Page 17 - © 2015 Cool Automation LTD

Commands ReferenceCoolMaster PRM24www.coolautomation.com© 2015 Cool Automation LTDRev 4.06DESCRIPTIONWithout parameters group command will list curren

Page 18

Commands ReferenceCoolMaster PRM25www.coolautomation.com© 2015 Cool Automation LTDRev 4.06A - Auto FanPPOn/off control for VAM units is performed with

Page 19 - 4.1.17 stat3,stat4

Commands ReferenceCoolMaster PRM26www.coolautomation.com© 2015 Cool Automation LTDRev 4.06OK>lock 101 +OKLock ALL for unit 101>lock 101 -OKUnLoc

Page 20 - Rev 4.06

Firmware UpdateCoolMaster PRM27www.coolautomation.com© 2015 Cool Automation LTDRev 4.065 Firmware Update5.1 Entering bootloader modeThe process of upd

Page 21 - 4.1.18 query

Firmware UpdateCoolMaster PRM28www.coolautomation.com© 2015 Cool Automation LTDRev 4.06CoolMaster will react with running address counter on its LCD s

Page 22 - 4.1.19 swing

3Contents3CoolMaster PRMwww.coolautomation.com© 2015 Cool Automation LTD

Page 23 - 4.1.21 group

Revisions HistoryCoolMaster PRM4www.coolautomation.com© 2015 Cool Automation LTDRev 4.061 Revisions HistoryDocument revision 4.06 Wednesday, January 0

Page 24 - 4.1.22 vam

RS232 InterfaceCoolMaster PRM5www.coolautomation.com© 2015 Cool Automation LTDRev 4.062 RS232 Interface2.1 Mechanical and Electrical SpecificationRS

Page 25 - 4.1.23 lock

RS232 InterfaceCoolMaster PRM6www.coolautomation.com© 2015 Cool Automation LTDRev 4.062.2 Port SettingsFor proper communication with Cool Master RS23

Page 26 - 4.1.24 wh

General Protocol DefinitionsCoolMaster PRM7www.coolautomation.com© 2015 Cool Automation LTDRev 4.063 General Protocol Definitions3.1 Message formatCom

Page 27 - 5 Firmware Update

General Protocol DefinitionsCoolMaster PRM8www.coolautomation.com© 2015 Cool Automation LTDRev 4.061011-012012-013103-10F9915-99UID format for Central

Page 28 - 5.3 Reboot

Commands ReferenceCoolMaster PRM9www.coolautomation.com© 2015 Cool Automation LTDRev 4.064 Commands Reference4.1 Cool Master Commandsalloffallonbootco

Commentaires sur ces manuels

Pas de commentaire